Verifi Concrete Quality Blog

Posts Tagged ‘measurement’

ASTM C94 Allows Water Addition in Transit

by Verifi

ASTM C94 / C94M (Standard Specification for Ready-Mixed Concrete) was revised in 2013 to allow water additions during transit for trucks equipped with automated slump monitoring and water measurement systems. Verifi meets these standards.

Why is this change being made?

Previously, ASTM C94 / 94M limited water additions to the job site so that an inspector or other qualified person could oversee any additions of water to ensure the maximum water content was not exceeded, the amount of water added was recorded, and the concrete was properly mixed. Truck-mounted equipment is now available to automatically add water in transit, measure and record all slump modifications. The ASTM C94 / C94M revision enables concrete suppliers, contractors, and engineers to take advantage of this technology.

What are the benefits of this change?

The addition of water in transit allows concrete to arrive at the job site at the correct slump and water content, ready to complete mixing and start discharging. This results in consistent quality concrete and faster construction.

What does the standard require?

The standard allows water addition in transit under the following conditions:

  • Water addition in transit must be permitted by the purchaser.
  • The truck must have automated equipment to monitor and report slump or slump flow based on pre-established correlations.
  • The truck must have a water meter with accuracy of +/-3%. At the request of the purchaser, the ready mix producer must provide calibration data for the water meter no older than 6 months.
  • The water added cannot exceed the maximum water content for the mix.
  • The concrete must be mixed 30 revolutions at mixing speed after the last addition of water and before the start of discharge. It is not necessary to mix concrete at mixing speed before the truck arrives at the job site, even if multiple water additions are made in transit.
  • The water added to the truck mixing drum must be provided on the batch ticket.